Suitable for oil free air handling to 25 psi not for distribution of compressed air or gas page 336 due to material cost variations prices subject to change.
Pvc schedule 80 temperature rating.
Schedule 80 pvc pipe dimensions pressure ratings maximum pvc service temperature 140 f pressure de rating at elevated temperatures the pressure ratings above are for water at 73 degrees fahrenheit.
The pressure capacity of the pvc diminishes from the baseline of 73 degrees as the temperature increases.
Check on line catalog www spearsmfg maximum pvc service temperature 140 f.
For pvc fitting schedule 40 and pvc fittings schedule 80 the optimal temperature at which pvc can operate at the highest psi would be 73 degrees fahrenheit.
As the temperature of the pvc increases the pressure that the pvc can withstand will decrease.
The maximum operating pressures derates with temperature.
Abs pipes pressure ratings pressure ratings of abs 1208 abs 1210 abs 1316 and abs 2112.
Astm d2467 04e1 standard specification for poly vinyl chloride pvc plastic pipe fittings schedule 80.
Max pressure 73 x derating factor schedule 80 pipe pvc pipe operating.
What is the maximum temperature rating of schedule 80 pvc.
230 psi x 0 40 92 psi max.
To determine the diminished pressure capacity you should use the following numbers.
The speci fi ed derating factors for pvc are suitable for pipe conveying water at.
The chart below will illustrate the pressure derating of pvc as temperatures increase.
To calculate elevated temperature rating use the following formula.
Gf harvel schedule 80 pvc systems are light tough and provide exceptional corrosion resistance for applications with operating temperatures up to 140 f 60 c.
Schedule 80 pvc can also be found in other colors like white and black though it is less common.
Pressure ratings pressure ratings of pipes and tubes and their fittings carbon steel stainless steel plastic copper and more.
Design strategies piping systems and design strategies documentation p id flow diagrams capacities and limits.
Maximum pvc service temperature 140 f pressure de rating at elevated temperatures the pressure ratings given above are for water non shock 73 f.
The maximum suggested temperature rating for schedule 80 pvc pipe and fittings is 140 degrees fahrenheit.
1 psi lb in 2 6 894 8 pa n m 2 1 inch 25 4 mm.
Multiply the working pressure rating of the selected pipe at 73 f by the appropriate de rating factor to determine the maximum working pressure rating of the pipe at the elevated temperature chosen.
At 80 degrees multiply the baseline pressure by 88 at 90 by 75 100 by 62 110 by 52 120 by 40 130 by 30 and 140 by 22.
Gf harvel pvc schedule 80 pipe and fittings exhibit consistent quality with uniform properties.
10 pvc sch 80 120 f.